The EUC-036SxxxDT(ST) series is a 36W, constant-current IP67 LED driver that operates from 90~305 Vac input with excellent power factor. It is created for architecture lighting, decorative lighting, tunnel and street lighting. The high efficiency of these drivers and metal case enable them to run cooler, significantly improving reliability and extending product life. To ensure trouble-free operation, protection is provided against input surge, output over voltage, short circuit, over load and over temperature. |
Back to products
Next product
40W LUD-DSF Series Programmable LED Driver by Inventronics
From: $34.20 $34.20 – $70.38
36W EUC-DT Series Constant Current LED Driver by Inventronics
$30.02 $30.02
- 36W EUC-DT Series Constant Current LED Driver by Inventronics
- Second Generation with Improved Performance
- Active Power Factor Correction (Typical 0.95)
- Constant Current Output
- Dimming Controls:
DT: 0-10V
ST: Non-Dimming - Input Surge Protection:
4kV DM, 6kV CM - Waterproof (IP67) and UL Dry / Damp / Wet Location
- Class 2 and SELV Output
- Improved Performance
- 5 Year Warranty
Related Product: 75W EUC-DT Series Constant Current LED Driver by Inventronics
Features
Technical Specifications
Model Number | Output Current | Input Voltage Range(1) | Output Voltage Range | Max Output Power | Typical Efficiency(2) | Power Factor |
---|---|---|---|---|---|---|
EUC- 036S035DT(ST)(6) | 350mA | 90-305Vac | 52-103Vdc | 36W | 89.0% | 0.96(120Vac) 0.95(220Vac) |
EUC- 036S045DT(ST)(6) | 450mA | 90-305Vac | 40-80Vdc | 36W | 88.0% | 0.96(120Vac) 0.95(220Vac) |
EUC- 036S070DT(ST)(3)(6) | 700mA | 90-305Vac | 26-52Vdc | 36W | 88.0% | 0.96(120Vac) 0.95(220Vac) |
EUC- 036S105DT(ST)(4)(6) | 1050mA | 90-305Vac | 18-35Vdc | 36W | 87.0% | 0.96(120Vac) 0.95(220Vac) |
EUC- 036S140DT(ST)(5)(6) | 1400mA | 90-305Vac | 13-26Vdc | 36W | 86.0% | 0.96(120Vac) 0.95(220Vac) |
EUC- 036S175DT(ST)(5)(6) | 1750mA | 90-305Vac | 11-21Vdc | 36W | 85.0% | 0.96(120Vac) 0.95(220Vac) |
Notes: (1) UL, FCC certified input voltage range: 100-277Vac; other certified input voltage range except UL & FCC: 100-240Vac (2) Measured at full load and 220 Vac input (3) Class 2 output (USR), Non-Class 2 output (CNR) (4) Class 2 output (USR), Class 2 output (CNR) only for wet location (5) Class 2 output (USR) and Class 2 output (CNR) for wet location (6) SELV output |
Additional information
Additional information
Dimensions | 6.77 × 1.77 × 1.38 in |
---|---|
Output Current | 350mA, 450mA, 700mA, 1050mA, 1400mA, 1750mA |