Features Automatic input voltage selection from 120 to 277 VAC, 50/60 Hz Over 2,000 events plus holiday schedules Advanced scheduling including relative events, such as fourth Thursday of November or first week of year 30 A rated contacts 100-hour supercapacitor eliminates the need for batteries USB connection for uploading, downloading and transferring programs Easy-to-follow on-screen menus for programming to-the-minute accuracy Non-volatile memory protects programming indefinitely Firmware can be upgraded in-field via USB or Ethernet Internally expandable, in 4-circuit increments, up to 16-circuits for 4, 8, and 12-circuit models PC App for easy scheduling or control, either remotely or through USB flash drive Supporting software downloads available |
Applications Indoor Lighting Control Machinery & Pump Controls Outdoor Lighting Control Timing/Scheduling ON/OFF
|
View cart “ET90115C Astronomic 365-Day 1-Circuit Electronic Control by Intermatic” has been added to your cart.
ET91215CR Outdoor 365-Day, 12-SPDT/6-DPDT Astronomic Electronic Control by Intermatic
$3,571.68
The ET90000 Series combines powerful and intuitive scheduling with truly maintenance-free convenience. The PC App and Mobile App provide real-time remote control, and the USB connection and Ethernet capabilities enable in-field updates.
Features
Technical Specifications
Backup Type | Supercapacitor |
---|---|
Input Voltage Range(s) | 120-277 VAC, 50/60 Hz |
Maximum ON/OFF Operations | 2000 |
Number Of Circuits | 12 |
Operation Mode | 365-day |
Switch Type | 6xDPDT, 12xSPDT |
Minimum ON/OFF Times | 1 Sec |
Operation Features | Astronomic, Holiday |
Electronic Series | ET90000 Series |
Maximum ON/OFF Times | 365 days |
Maximum Power Consumption (W) | 50W |
Minimum Pulse Time | 1 Sec |
Wiring Option | Terminals |
ON/OFF Operations | 2000 |
Backup Protection Time | 100 Hour |
Resistive (NO) | 20 A @ 28 VDC, 30 A, 12 VAC, 50 Hz, 30 A, 12 VAC, 60 Hz, 30 A, 120 VAC, 50 Hz, 30 A, 120 VAC, 60 Hz, 30 A, 18 VAC, 50 Hz, 30 A, 18 VAC, 60 Hz, 30 A, 208 VAC, 50 Hz, 30 A, 208 VAC, 60 Hz, 30 A, 24 VAC, 50 Hz, 30 A, 24 VAC, 60 Hz, 30 A, 240 VAC, 50 Hz, 30 A, 240 VAC, 60 Hz |
Warranty Period | 3-Year limited |
Backup Restoration Time | 30 Minutes |
Data Transfer Options | Ethernet Optional/USB |
Electronic Ballast (NO) | 8 A, 120 VAC, 50 Hz, 8 A, 120 VAC, 60 Hz, 8 A, 208 VAC, 50 Hz, 8 A, 208 VAC, 60 Hz, 8 A, 240 VAC, 50 Hz, 8 A, 240 VAC, 60 Hz, 8 A, 277 VAC, 50 Hz, 8 A, 277 VAC, 60 Hz |
Electronic Ballast Load Ratings NO Ranges | 8 A, 120-277 VAC, 50/60 Hz |
General Purpose (NC) | 10 A, 120 VAC, 50 Hz, 10 A, 120 VAC, 60 Hz, 10 A, 12 VAC, 50 Hz, 10 A, 12 VAC, 60 Hz, 10 A, 18 VAC, 50 Hz, 10 A, 18 VAC, 60 Hz, 10 A, 208 VAC, 50 Hz, 10 A, 208 VAC, 60 Hz, 10 A, 240 VAC, 50 Hz, 10 A, 240 VAC, 60 Hz, 10 A, 24 VAC, 50 Hz, 10 A, 24 VAC, 60 Hz |
General Purpose (NC) Range(s) | 10 A, 12-240 VAC, 50/60 Hz |
Magnetic Ballast (NC) | 3 A, 120 VAC, 50 Hz, 3 A, 120 VAC, 60 Hz, 3 A, 208 VAC, 50 Hz, 3 A, 208 VAC, 60 Hz, 3 A, 240 VAC, 50 Hz, 3 A, 240 VAC, 60 Hz, 3 A, 277 VAC, 50 Hz, 3 A, 277 VAC, 60 Hz |
Magnetic Ballast (NC) Range(s) | 3 A, 120-277 VAC, 50/60 Hz |
Magnetic Ballast (NO) | 20 A, 120 VAC, 50 Hz, 20 A, 120 VAC, 60 Hz, 20 A, 208 VAC, 50 Hz, 20 A, 208 VAC, 60 Hz, 20 A, 240 VAC, 50 Hz, 20 A, 240 VAC, 60 Hz, 20 A, 277 VAC, 50 Hz, 20 A, 277 VAC, 60 Hz |
Magnetic Ballast (NO) Range(s) | 20 A, 120-277 VAC, 50/60 Hz |
Maximum Pulse Time | 23 hours, 59 minutes |
Motor (NC) | 1/4 HP, 120 VAC, 50 Hz, 1/4 HP, 120 VAC, 60 Hz, 1/2 HP, 240 VAC, 50 Hz, 1/2 HP, 240 VAC, 60 Hz |
Motor (NO) | 1 HP, 120 VAC, 50 Hz, 1 HP, 120 VAC, 60 Hz, 2 HP, 240 VAC, 50 Hz, 2 HP, 240 VAC, 60 Hz |
Motor Load Ratings NC Ranges | 1/4 HP, 120 VAC, 50/60 Hz; 1/2 HP, 240 VAC, 50/60 Hz |
Motor Load Ratings NO Ranges | 1 HP, 120 VAC, 50/60 Hz; 2 HP, 240 VAC, 50/60 Hz |
Pilot Duty (NC) | 275 VA, 120 VAC, 50 Hz, 275 VA, 120 VAC, 60 Hz, 275 VA, 208 VAC, 50 Hz, 275 VA, 208 VAC, 60 Hz, 275 VA, 240 VAC, 50 Hz, 275 VA, 240 VAC, 60 Hz |
Pilot Duty (NC) Range(s) | 275 VA, 120-240 VAC, 50/60 Hz |
Pilot Duty (NO) | 470 VA, 120 VAC, 50 Hz, 470 VA, 120 VAC, 60 Hz, 470 VA, 208 VAC, 50 Hz, 470 VA, 208 VAC, 60 Hz, 470 VA, 240 VAC, 50 Hz, 470 VA, 240 VAC, 60 Hz |
Pilot Duty (NO) Range(s) | 470 VA, 120-240 VAC, 50/60 Hz |
Resistive (NC) | 10 A, 12 VAC, 50 Hz, 10 A, 12 VAC, 60 Hz, 10 A, 120 VAC, 50 Hz, 10 A, 120 VAC, 60 Hz, 10 A, 18 VAC, 50 Hz, 10 A, 18 VAC, 60 Hz, 10 A, 208 VAC, 50 Hz, 10 A, 208 VAC, 60 Hz, 10 A, 24 VAC, 50 Hz, 10 A, 24 VAC, 60 Hz, 10 A, 240 VAC, 50 Hz, 10 A, 240 VAC, 60 Hz, 10 A, 28 VDC |
Resistive (NC) Range(s) | 10 A, 28 VDC; 10 A, 12-240 VAC, 50/60 Hz |
Resistive (NO) Range(s) | 20 A, 28 VDC; 30 A, 12-240 VAC, 50/60 Hz |
Tungsten (NO) Load Ratings | 5 A, 110 VAC, 50 Hz, 5 A, 110 VAC, 60 Hz, 5 A, 115 VAC, 50 Hz, 5 A, 115 VAC, 60 Hz, 5 A, 12 VAC, 50 Hz, 5 A, 12 VAC, 60 Hz, 5 A, 120 VAC, 50 Hz, 5 A, 120 VAC, 60 Hz, 5 A, 24 VAC, 50 Hz, 5 A, 24 VAC, 60 Hz, 5 A, 50 VAC, 50 Hz, 5 A, 50 VAC, 60 Hz |
Tungsten (NO) Range(s) | 5 A, 12-120 VAC, 50/60 Hz |
Voltage Selection Type | Auto Voltage |
Operating Temperature (°F) | -40° – 140° |
Product Dimensions (in) | Outdoor: 5.4″ x 17.9″ x 12.7″ |